spacer gif spacer gif spacer gif spacer gif spacer gif
 QUICK SEARCH:   [advanced]


spacer gif
     Home     Help     Feedback     Subscriptions     Archive     Search     Table of Contents    


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by de Lange, F.
Right arrow Articles by Figdor, C. G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by de Lange, F.
Right arrow Articles by Figdor, C. G.
Journal of Cell Science 114, 4153-4160 (2001)
© 2001 The Company of Biologists Limited


COMMENTARY

Cell biology beyond the diffraction limit: near-field scanning optical microscopy

Frank de Lange1, Alessandra Cambi1, Richard Huijbens1, Bärbel de Bakker2, Wouter Rensen2, Maria Garcia-Parajo2, Niek van Hulst2 and Carl G. Figdor1,*

1 Department of Tumor Immunology, University Medical Center Nijmegen, NCMLS/187 TIL, PO Box 9101, 6500HB Nijmegen, The Netherlands
2 Applied Optics Group, Faculty of Applied Physics and MESA+ Research Institute, University of Twente, PO Box 217, 7500AE Enschede, The Netherlands

*Author for correspondence (e-mail: c.figdor{at}mailbox.kun.nl)

Throughout the years, fluorescence microscopy has proven to be an extremely versatile tool for cell biologists to study live cells. Its high sensitivity and non-invasiveness, together with the ever-growing spectrum of sophisticated fluorescent indicators, ensure that it will continue to have a prominent role in the future. A drawback of light microscopy is the fundamental limit of the attainable spatial resolution – ~250 nm – dictated by the laws of diffraction. The challenge to break this diffraction limit has led to the development of several novel imaging techniques. One of them, near-field scanning optical microscopy (NSOM), allows fluorescence imaging at a resolution of only a few tens of nanometers and, because of the extremely small near-field excitation volume, reduces background fluorescence from the cytoplasm to the extent that single-molecule detection sensitivity becomes within reach. NSOM allows detection of individual fluorescent proteins as part of multimolecular complexes on the surface of fixed cells, and similar results should be achievable under physiological conditions in the near future.

Key words: Super-resolution, Near-field scanning optical microscopy, Single-molecule detection, Distribution, Cell surface, Membrane, GFP




This article has been cited by other articles:


Home page
BloodHome page
Y. Chen, L. Shao, Z. Ali, J. Cai, and Z. W. Chen
NSOM/QD-based nanoscale immunofluorescence imaging of antigen-specific T-cell receptor responses during an in vivo clonal V{gamma}2V{delta}2 T-cell expansion
Blood, April 15, 2008; 111(8): 4220 - 4232.
[Abstract] [Full Text] [PDF]


Home page
Biophys. JHome page
Z. Gryczynski
FCS Imaging--A Way to Look at Cellular Processes
Biophys. J., March 15, 2008; 94(6): 1943 - 1944.
[Full Text] [PDF]


Home page
J. Cell Sci.Home page
B. I. de Bakker, A. Bodnar, E. M. H. P. van Dijk, G. Vamosi, S. Damjanovich, T. A. Waldmann, N. F. van Hulst, A. Jenei, and M. F. Garcia-Parajo
Nanometer-scale organization of the alpha subunits of the receptors for IL2 and IL15 in human T lymphoma cells
J. Cell Sci., March 1, 2008; 121(5): 627 - 633.
[Abstract] [Full Text] [PDF]


Home page
Proc. Natl. Acad. Sci. USAHome page
D. J. Sirbuly, M. Law, P. Pauzauskie, H. Yan, A. V. Maslov, K. Knutsen, C.-Z. Ning, R. J. Saykally, and P. Yang
Optical routing and sensing with nanowire assemblies
PNAS, May 31, 2005; 102(22): 7800 - 7805.
[Abstract] [Full Text] [PDF]


Home page
Biophys. JHome page
K. T. Samiee, M. Foquet, L. Guo, E. C. Cox, and H. G. Craighead
{lambda}-Repressor Oligomerization Kinetics at High Concentrations Using Fluorescence Correlation Spectroscopy in Zero-Mode Waveguides
Biophys. J., March 1, 2005; 88(3): 2145 - 2153.
[Abstract] [Full Text] [PDF]


Home page
Biophys. JHome page
A. Ianoul, M. Street, D. Grant, J. Pezacki, R. S. Taylor, and L. J. Johnston
Near-Field Scanning Fluorescence Microscopy Study of Ion Channel Clusters in Cardiac Myocyte Membranes
Biophys. J., November 1, 2004; 87(5): 3525 - 3535.
[Abstract] [Full Text] [PDF]


Home page
ScienceHome page
D. J. Stephens and V. J. Allan
Light Microscopy Techniques for Live Cell Imaging
Science, April 4, 2003; 300(5616): 82 - 86.
[Abstract] [Full Text] [PDF]


Home page
ScienceHome page
M. J. Levene, J. Korlach, S. W. Turner, M. Foquet, H. G. Craighead, and W. W. Webb
Zero-Mode Waveguides for Single-Molecule Analysis at High Concentrations
Science, January 31, 2003; 299(5607): 682 - 686.
[Abstract] [Full Text] [PDF]


Home page
Proc. Natl. Acad. Sci. USAHome page
J. Gorelik, A. Shevchuk, M. Ramalho, M. Elliott, C. Lei, C. F. Higgins, M. J. Lab, D. Klenerman, N. Krauzewicz, and Y. Korchev
Scanning surface confocal microscopy for simultaneous topographical and fluorescence imaging: Application to single virus-like particle entry into a cell
PNAS, December 10, 2002; 99(25): 16018 - 16023.
[Abstract] [Full Text] [PDF]




© The Company of Biologists Ltd 2001