spacer gif spacer gif spacer gif spacer gif spacer gif
 QUICK SEARCH:   [advanced]


spacer gif
     Home     Help     Feedback     Subscriptions     Archive     Search     Table of Contents    


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by GRAY, E. G.
Right arrow Articles by WILLIS, R. A.
Right arrow Search for Related Content
PubMed
Right arrow Articles by GRAY, E. G.
Right arrow Articles by WILLIS, R. A.

Journal of Cell Science, Vol 3, 309-326, Copyright © 1968 by Company of Biologists

Submitted on October 25, 1967

Problems Of Electron Stereoscopy Of Biological Tissue

E. G. GRAY 1 and R. A. WILLIS 1

1 Department of Anatomy, University College London, Gower Street, London, W.C.1

A detailed study of stereoscopy of tissue sections with the transmission electron microscope has been carried out using different tilt angles and staining techniques, aided with models. Pictures with tilt angle difference of 20° or more can be fused to give pairs of micrographs showing stereodepth. Cytoplasmic filaments, glycogen and ribosomal granules give good stereodepth. Oblique membranes, especially when stained with lead or phosphotungstic acid, give good depth in stereo-pairs but membranes running more vertically in the section do not. A theory, based on the ‘transparency factor’ that is a feature of transmission electron microscopy, is given to account for this discrepancy. A learning process is involved in achieving depth perception when viewing stereo-pairs of electron micrographs of tissue sections. Complex structures often cannot be perceived in depth even after prolonged scrutiny through the stereoscope. Where structures overlap in the thickness of the section, they can be ‘separated out’ with stereoscopy and in this way clarified, for depending on which micrograph of a stereo-pair is presented to which eye, a structure can be made to appear either in the front or the back of a section. In general, problems of depth perception in stereo-pairs of micrographs obtained with transmission electron microscopy arise because with our normal everyday vision using reflected light, we look at things, whereas with the electron microscope using a transmission electron beam we look through things.

Submitted on October 25, 1967







© The Company of Biologists Ltd 1968