spacer gif spacer gif spacer gif spacer gif spacer gif
 QUICK SEARCH:   [advanced]


spacer gif
     Home     Help     Feedback     Subscriptions     Archive     Search     Table of Contents    


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Dow, J. A.
Right arrow Articles by Crocket, K. V.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Dow, J. A.
Right arrow Articles by Crocket, K. V.

Journal of Cell Science, Vol 87, Issue 1 171-182, Copyright © 1987 by Company of Biologists


JOURNAL ARTICLES

A simple microcomputer-based system for real-time analysis of cell behaviour

JA Dow, JM Lackie and KV Crocket
Department of Cell Biology, University of Glasgow, Scotland.

An image analysis package based on a BBC microcomputer has been developed, which can simultaneously track many moving cells in vitro. Cells (rabbit neutrophil leucocytes, BHK C13 fibroblasts, or PC12 phaeochromocytoma cells) are viewed under phase optics with a monochrome TV camera, and the signal digitized. Successive frames are acquired by the computer as a 640 X 256 pixel array. Under controlled lighting conditions, cells can readily be isolated from the background by binary filtering. In real-time tracking, the positions of a given cell in successive frames are obtained by searching the area around the cell's centroid in the previous frame. A simple box-search algorithm is described, which proves highly successful at low cell densities. The resilience of different search algorithms to various exceptional conditions (such as collisions) is discussed. The success of this system in real-time tracking is largely dependent upon the leisurely speed of movement of cells, and on obtaining a clean, high quality optical image to analyse. The limitations of this technique for different cell types, and the possible configurations of more sophisticated hardware, are outlined. This system provides a versatile and automated solution to the problem of studying the movement of tissue cells.


This article has been cited by other articles:


Home page
J. Cell Sci.Home page
S Chettibi, A. Lawrence, J. Young, P. Lawrence, and R. Stevenson
Dispersive locomotion of human neutrophils in response to a steroid-induced factor from monocytes
J. Cell Sci., January 11, 1994; 107(11): 3173 - 3181.
[Abstract] [PDF]




© The Company of Biologists Ltd 1987