spacer gif spacer gif spacer gif spacer gif spacer gif
 QUICK SEARCH:   [advanced]


spacer gif
     Home     Help     Feedback     Subscriptions     Archive     Search     Table of Contents    


This Article
Right arrow Summary Freely available
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by de Lange, F.
Right arrow Articles by Figdor, C. G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by de Lange, F.
Right arrow Articles by Figdor, C. G.

Cell biology beyond the diffraction limit: near-field scanning optical microscopy

Frank de Lange1, Alessandra Cambi1, Richard Huijbens1, Bärbel de Bakker2, Wouter Rensen2, Maria Garcia-Parajo2, Niek van Hulst2 and Carl G. Figdor1,*

1 Department of Tumor Immunology, University Medical Center Nijmegen, NCMLS/187 TIL, PO Box 9101, 6500HB Nijmegen, The Netherlands
2 Applied Optics Group, Faculty of Applied Physics and MESA+ Research Institute, University of Twente, PO Box 217, 7500AE Enschede, The Netherlands



View larger version (74K):

[in a new window]
 
Fig. 1. The principle of scanning probe microscopy. In AFM and NSOM, a sharp probe is used to map the topographic features on the sample surface accurately. This is done by physically scanning the probe over the surface while maintaining a constant probe-sample distance by force feedback.

 


View larger version (21K):

[in a new window]
 
Fig. 2. Schematic lay out of a near-field scanning optical microscope. The NSOM probe is a tapered optical fiber (Fig. 3A). Laser light is coupled into the fiber and is used to excite fluorophores as the probe scans the sample surface. The probe-sample distance is maintained constant at <10 nm during scanning by shear-force-based distance detection in combination with an electronic feedback system controlling the piezoelectric scan stage. Fluorescence is collected by a conventional inverted microscope. Dual-channel optical detection allows wavelength and/or polarization discrimination.

 


View larger version (71K):

[in a new window]
 
Fig. 3. The near-field optical probe. (A) An optical fiber is pulled to a final diameter of 20-120 nm and subsequently coated with aluminum. This coating serves to confine the light to the tip region. A subsequent etching step results in a flat and circular endpoint and aperture. The aperture functions as a miniature light source, and its diameter primarily determines the optical resolution of the microscope. (B) The principle of surface-specific excitation. The optical near-field generated at the aperture has significant intensity only in a layer of <100 nm from the aperture; lower lying fluorophores are therefore not excited. Hence, background fluorescence is effectively suppressed. This forms the basis for the high optical detection sensitivity of this technique.

 


View larger version (55K):

[in a new window]
 
Fig. 4. (A) Single molecule detection on cells by NSOM. This figure shows a 40 nm optical resolution near-field ‘zoom-in’ on the indicated area (3.2 x 3.2 µm2) in the bright-field image of a fibroblast expressing LFA-1-GFP. GFP excitation is accomplished using 488 nm light (Ar-Kr laser line) linearly polarized along 90°. Fluorescence is collected by a 1.3 numerical aperture oil-immersion objective in combination with standard optical filters. A polarizing beam-splitter cube (Newport, Fountain Valley, CA) is used to split the fluorescence signal into two perpendicular polarized components (compare with Fig. 2). Both signals are then detected by photon-counting avalanche photodiode detectors (APD, SPCM-100, EG&G Electro optics, Quebec). The red/green color-coding of the signals reflects the orientation of the GFP molecules in the plane of the sample. Examples of clustered molecules (arrows) as well as examples showing clear single-molecule detection sensitivity are indicated (circles and squares). The squares show the fast-blinking behavior typical of single molecule GFP fluorescence. The circles present demonstrations of discrete photodissociation phenomena. (B) Estimation of the resolution in the near-field image. This figure shows a line trace through the feature marked with the hexagon in the near-field image. The full width at half maximum (FWHM; arrows) of such traces can be used to obtain an estimate for the maximal resolution (half the FWHM) in the near-field image. On this basis, we estimate the resolution in the near-field image to be ~40 nm.

 





© The Company of Biologists Ltd 2001